CALIBRATION OF ORIFICEMETER
CALIBRATION OF ORIFICEMETER
AIM: To
determine the co-efficient of discharge Cd of Orifice meter
EQUIPMENTS AND COMPONENTS:
Orifice filled with a pipe of known
diameter, manometer, collecting tank, stop watch.
THEORY:
Orifice
is a simple device to measure the flow in a pipe by reducing the flow passage
in one section. The pressure difference is created between two sections. The
measurement of pressure difference between two sections determine Cd of the
Orifice.
Since
the diameter at passage of Orifice is less than that of pipe as the time
reaches maximum value the pressure becomes less or pressure tap is provided at
this section another pressure tap is provided at a distance of 0.9 to 1.1 times
the diameter of pipe from Orifice plate where the pressure is maximum. From the
collecting tank we can measure the actual discharge using the formulae.
PROCEDURE:
1. Diameter of pipe and Orifice are
noted down
2. Air in the manometer pipe is removed
by allowing it to pass through the pipe.
3. The inlet and outlet values are
brought to required position.
4. For a constant discharge the readings
of manometer are noted down.
5. The above procedure is repeated for
difference values of discharge.
6. The graph of Qact v/s H is plotted,
value of Cd is calculated